Let's learn about the thin plate pretreatment line
I. Dust collector dust contains too much projectile
Separator air volume is too large, appropriate adjustment of the wind baffle, until the dust removal effect can be guaranteed, but not suck out the projectile for good.
II. Dust collector dust removal efficiency is low
1. Wrong wiring of dust collector fan, fan reversal, rewiring.
2. Poorly installed or broken filter cartridges in the dust collector, or lack of filter cartridges.
3. poor sealing at the dust collector duct connection to ensure the sealing of the components.
4. The cleaned workpiece does not fall sand according to the requirements, too much sand residue, dust inlet wind dust content is too high.
5. Dust collector back-blowing mechanism is not enabled, or enabled for a small number of times, dust blocking the canister, timely removal of dust attached to the canister.
III. Bucket elevator does not run
1. clamped, remove the bottom of the elevator too large particles.
2. Belt slippage, adjust the drive wheel tightening device, tighten the belt.
3. too much pellets at the bottom of the elevator, stop and remove the pellets in order.
Four. Shot blast cleaning machine cleaning effect is not ideal
1. Insufficient supply of pellets, proper addition of new pellets.
2. Shot blasting machine projection direction is not accurate, adjust the shot blasting machine orientation set window position.
3. The particle size of the pellet material disagreement, re-election pellet material particle size.
4. Pill material lump or use too long, replace the pill material.
V. Clean room door switch does not work or can not open
Door shaft lubrication is not good, refill lubricant.
Six. Machine driving and parking action is not agile or not according to the prescribed action
1. The electrical components are damaged, check and replace.
2. Electrical box dust, dirt, too much, electrical contact points poor contact.
3. Time relay dust, dirt, too much, electrical contact points poor contact.
VII. Screw conveyor does not run
1. Pill material blockage, stop and clear the pills in order.
2. Spiral shaft bending, correct or polish the outer diameter of the blade.
3. Spiral shaft head weld fracture, re-welding.
VIII. Separator separation effect is poor
1. Uneven flow curtain, adjust the flow control board to reach the full curtain.
2. The wind speed of the separation area is not suitable, adjust the butterfly valve of the wind mouth of the separator, so that the wind speed of the separation area reaches 4~5m/s, and adjust the position of the first and second adjustment plate.